• 6101t6 Aluminum Flat Bar for Electrical Control Panel
  • 6101t6 Aluminum Flat Bar for Electrical Control Panel
  • 6101t6 Aluminum Flat Bar for Electrical Control Panel
  • 6101t6 Aluminum Flat Bar for Electrical Control Panel
  • 6101t6 Aluminum Flat Bar for Electrical Control Panel
  • 6101t6 Aluminum Flat Bar for Electrical Control Panel

6101t6 Aluminum Flat Bar for Electrical Control Panel

Shape: Rectangular
Application: Busbar, Electrical Control Panel
Certification: ASTM, GB, EN
Technique: Extruded
Grade: 6000 Series
Temper: T3 - T8
Samples:
US$ 0/Piece 1 Piece(Min.Order)
| Request Sample
Customization:
Gold Member Since 2011

Suppliers with verified business licenses

Manufacturer/Factory

Basic Info.

Model NO.
6101
Surface Treatment
Mill Finish
Alloy
Alloy
Alloy No.
6101
Tempers
T6
Thickness
0.5-150 mm
Length
1000 - 10000mm
Width
50-2700mm
Transport Package
Wooden Pallet
Specification
busbar
Trademark
Signi aluminum
Origin
Henan China
HS Code
76061190
Production Capacity
50000mt/Month

Product Description

6101T6 aluminum flat bar for Electrical control panel

6101 has considerably higher yield strength and better creep resistance than 1350. The alloy contained magnesium and silicon for high mechanical strength without significant reduction in conductivity. The strength of this alloy (6101) is obtained by suitable heat treaunents, occasionally combined with some cold work.

The common size of aluminum busbar, used for electrical control panel

a.       25MM X 6MM AL BUSBAR , 6101 GRADE, T6
b.      25MM X 10MM AL BUSBAR , 6101 GRADE, T6
c.       40MM X 6MM AL BUSBAR , 6101 GRADE, T6
d.      40MM X 10MM AL BUSBAR , 6101 GRADE, T6
e.      50MM X 6MM AL BUSBAR , 6101 GRADE, T6
f.        50MM X 10MM AL BUSBAR , 6101 GRADE, T6
g.       60MM X 6MM AL BUSBAR , 6101 GRADE, T6
h.      60MM X 10MM AL BUSBAR , 6101 GRADE, T6
i.         80MM X 6MM AL BUSBAR , 6101 GRADE, T6
j.        80MM X 10MM AL BUSBAR , 6101 GRADE, T6
k.       100MM X 6MM AL BUSBAR , 6101 GRADE, T6
l.         100MM X 10MM AL BUSBAR , 6101 GRADE, T6
m.    125MM X 6MM AL BUSBAR , 6101 GRADE, T6
n.      125MM X 10MM AL BUSBAR , 6101 GRADE, T6
o.      150MM X 6MM AL BUSBAR , 6101 GRADE, T6
p.      150MM X 10MM AL BUSBAR , 6101 GRADE, T6
q.      160MM X 6MM AL BUSBAR , 6101 GRADE, T6
r.        160MM X 10MM AL BUSBAR , 6101 GRADE, T6

6101t6 Aluminum Flat Bar for Electrical Control Panel
6101t6 Aluminum Flat Bar for Electrical Control Panel

6101t6 Aluminum Flat Bar for Electrical Control Panel6101t6 Aluminum Flat Bar for Electrical Control Panel

Physical and Electrical Properties of Aluminum Wrought Bus Conductor Alloys
                                                               (ASTM B 236,B 317,and The Aluminum Association)
Applying to all alloys and tempers of wrought 
alloys, typical values.
 
Weight, lb/cu in. (rounded) 0.098
Specific heat, cal/gm/ºC or BTU/LB/F 0.214 
at 70ºC for 1350 and 0.220 for 6101(e).
 
Coefficient of thermat expansion (linear)/ºC
 0.000023.
Specific gravity - 2.70.
Modulus of Elasticity, Typical, psi 10 * 106, up to 2% higher
 in compression.
 
Note : if two values are shown, the more favorable is "typical"; 
the less favorable is designated "minimum" provided a higher
 value is favorable. Otherwise the term "guaranteed" is 
sometimes used.
 
Properties Alloy and Temper
  1350
Any Temper
6101
 -T6
6101
-T61
6101
-T63
6101
-T64
6101
-T65
6101-T6
Typical
6063
-T6 typical
Thermal conductivity at 20ºC,watts/sq.
 In /in /ºC
5.9-6.0 5.3-5.4 5.5-5.6 5.4-5.5 5.7-5.8 5.7-5.8 3.9 5.1
Volume electrical conductivity at 20ºC 
percent IACS(a).
61-62 55-56 57-58 56-57 59.5-60.5 56.5-57.5 42.43 63(a)
Electrical resistivity (de) at 20ºC (68F)
 microhms/sq.in./ft(c).
13.35-
13.14
14.81-
14.55
14.29-
14.04
14.55-
14.29
13.69-
13.46
14.42-
14.17
19.39-
18.94
15.37
Temperature coefficient of electrical 
resistance at 20ºC /ºC(d).
0.00403-
0.00410
0.00363-
0.00370
0.00377-
0.00383
0.00370-
0.00377
0.00393-
0.00400
0.00373-
0.00380
0.00284-
0.00277
0.00350

(a) Typical conductivities of 6101 alloys from Standards of The Aluminum Association. The conductivity of 6063·T6 alloy pipe for outdoor service may be taken as 55.% lACS for current ratings, per NEMA Standard.
(b) To obtain de resistance at 20"'C in microhms multiply table value by length in feet and divide by cross sectional area in sq. in.
(c) Increasing by 0.018 for each 100"C above 70'C (specific heat).
(d) The higher of a pair of coettlclents corresponds to the higher vafue of the pair of conductivity values.


                                          Temperature Coefficients of Resistance (dc) for Bus-conductor Aluminum Alloys 
                                                            And Representative Value for Commercial Copper Bus Bar
 
Aluminum Alloys and Tempers, And Conductivity % (IACS) (a)
  6061-
T6
Typical
6063-T6
Typical
6101-T6
Minimum
6101-T63
Minimum
6101-T6
Minimum
6101-T61
Typical
  6101-T64
Minimum
  1350 
Minimum
1350 
Typical
Representative 
Value
 Commercial 
Copper 
Busbar
% IACS
Temp. C.
40% 53%
(b)
55% 56% 57% 58% 59% 59.5% 60% 61% 62% 98%
0
10
20
25
.00279
.00271
.00264
.00261
.00377
.00363
.00350
.00344
.00392
.00377
.00363
.00357
.00400
.00384
.00370
.00363
.00407
.00391
.00377
.00370
.00415
.00398
.00383
.00376
.00423
.00406
.00390
.00382
.00427
.00409
.00393
.00386
.00431
.00413
.00396
.00388
.00438
.00420
.00403
.00395
.00446
.00427
.00410
.00401
.00417
.00401
.00385
.00378
30
40
50
60
.00257
.00251
.00245
.00239
.00338
.00327
.00317
.00307
.00351
.00339
.00328
.00317
.00357
.00344
.00333
.00322
.00363
.00350
.00338
.00327
.00369
.00356
.00344
.00332
.00375
.00362
.00349
.00337
.00378
.00364
.00352
.00340
.00381
.00367
.00354
.00342
.00387
.00373
.00360
.00347
.00393
.00379
.00365
.00352
.00371
.00358
.00345
.00334
70
80
90
100
.00233
.00228
.00223
.00218
.00298
.00289
.00281
.00274
.00307
.00298
.00290
.00282
.00312
.00303
.00294
.00285
.00316
.00307
.00298
.00289
.00322
.00312
.00302
.00293
.00326
.00316
.00306
.00297
.00329
.00318
.00308
.00299
.00331
.00320
.00310
.00301
.00335
.00325
.00314
.00305
.00340
.00329
.00318
.00309
.00323
.00313
.00303
.00294
 
(a) For alloys not shown. obtain conductivities from Table 13·2, and interpolate from the listed values.
 
(b) Per note on Table 1;3.2, 55% conductivity is much used as design basis for 6063·T6 alloys for tubes, hence coefficients should be taken from the column, headed 55%.

                                            Mechanical Properties of Aluminum Bus Conductor and Related Alloys
                            (The Aluminum Association ; ASTM B 236, B 241, and B 429; and Manufacturer's Listings)
 
Product Alloy and Temper Thickness in
Ultimates
Tensile Strength (ksi)
At 20 (68.F)
Typical 
Ultimate
Typical Yield Typical(a) 
Elongation
(Percent - in 2 in. 
Or 4 Dia)
Minimum 
Ultimate
Minimum 
Yield
Extruded rod, bar tube,
pipe and shapes
1350-H111 All 8.5 3.5     35.0
6101-T6 0.125-0.500 29.0 25.0 32.0 28.0 15.0
6101-T61 0.125-0.749
0.750-1.499
1.500-2.000
20.0
18.0
15.0
15.0
11.0
8.0
     
6101-T63
6101-H111
6101-T64
6101-T65
0.125-0.500
0.250-2.000
0.125-1.000
0.125-0.749
27.0
12.0
15.0
25.0
22.0
8.0
8.0
20.0
14.0 11.0  
Extruded pipe(c) 6061-T6
6063-T6
Pipe size 1.0 & 
over Pipe sizes,all
38.0
30.0
 
35.0
25.0
45.0
35.0
40.0
31.0
10.0 min
8.0 min
Rolled bar 1350-H12 0.125-1.000 12.0 8.0 14.0 12.0  
Sawed-plate bar or sheet 1350-H112 0.125-0.499
0.500-1.000
1.001-3.000
11.0
10.0
9.0
6.0
4.0
3.5
    10.0min
16.0min
22.0min
Rolled sheet
(for shearing or forming)
1350
1350-H12
1350-H14
0.020-0.249 8.0
12.0
14.0
  12.0
14.0
16.0
4.0
12.0
14.0
20-30 min
4-9 min
3-6 min
1350-H16
1350-H18
0.020-0.125 16.0
18.0
  18.0 16.0 2-4 min
2-4 min
Cast Alloy for Bus 1350-F 
1050
1 in. And up     8.5 3.5 35.0
Cast Alloy for Fittings A356.0-T61   37.0       5.0
 
6101t6 Aluminum Flat Bar for Electrical Control Panel
6101t6 Aluminum Flat Bar for Electrical Control Panel

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now